HomeProductsContact UsSearch
Laboratory HomeMarkets / ApplicationsProductsFind product information, technical articles, and other support documentsSupportEvents
Shopping Cart
Shopping Cart
Lab Store
Check Out
Quick Order
My Account
Live Help
Pall Preferred
Print
Email
Download PDF
 

Acro® 50 Vent Devices with Emflon® II Membrane

descriptionapplicationsspecificationsordering
Acro® 50 Vent Devices with Emflon® II Membrane
Ideal for use in air/gas and vent applications with proprietary, low- pressure-drop, hydrophobic polyvinylidene fluoride (PVDF) Emflon II membrane
  • Emflon II membrane filters have a removal rating of 0.2 µm in liquid service and less than 0.02 µm particulate for air/gas applications.
  • Connects easily to hoses of various sizes in-line or as a final filter.
  • Light weight (< 27 grams), prevents crimping of tubing.
  • Stable with gamma irradiation.
  • Excellent for disposable systems.  Eliminates cleaning validation.
  • Venting of bioreactors, fermentation tanks, and carboys.
  • Sterile gas purging of culture vessels.
  • Ideal for attachment to disposable systems that need to undergo gamma irradiation.
Materials of Construction
Filter Media: Emflon II membrane (hydrophobic PVDF)
Housing: Polypropylene

Effective Filtration Area
20 cm2

Inlet/Outlet Connections
Stepped hose barbs, 6.4 - 12.7 mm (1/4 - 1/2 in.) diameter with slip luer ID in the hose barb

Maximum Operating Temperature
60 °C  (140 °F)

Maximum Operating Pressure
4.1 bar (410 kPa, 60 psi) at ambient temperature

Recommended Integrity Test
Minimum Bubble Point -
60% IPA/40% Water (v:v)
0.8 bar (80 kPa, 12 psi)

Typical Air Flow Rate
27 L/min at 1.0 bar (100 kPa, 15 psi)

Endotoxin Level
< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test

Biological Safety
Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>

Bacterial Retention
Lot samples retain a minimum of 107 cfu/cm2 of B. diminuta per modified ASTM F838-83

Sterilization
Provided non-sterile. Stable with gamma irradiation up to 50 kilogray. Can be sterilized by autoclaving at 121 °C (250 °F) for 20 min.
Maximum autoclave stability, three cycles at 131 °C (268 °F) for 30 min.

Part Number Description Pkg Price Qty
Acro® 50 Vent Filter with Emflon® Membrane
A50V002P2NV Hose barb, no vent, 0.2 µm 100% integrity tested during manufacturing 100/pkg 1,373.68
A50V002P2 Hose barb with vent, 0.2 µm 3/pkg 39.41
4252 Integrity test kit (includes pressure gauge, 3-way valve, and 10 mL syringe) 1/pkg 78.26


Contact Customer Service at 800-521-1520 for possible lead-time and date item will be available to ship.



Your shopping cart is empty.
*US List Price applies only to products delivered within the US. These prices do not reflect duties, taxes or tariffs, which may apply to purchases made outside of the US. See our General Limited Warranty.