Use for filtration of batches up to 50 liters (AcroPak 500 capsules, formerly SuporCap 50, CritiCap, and CritiCap-M capsules), 100 liters (AcroPak 1000 capsules, formerly SuporCap 100, CritiCap, and CritiCap-M capsules) and 150 liters (AcroPak 1500 capsule) for applications such as:
- Large volume media preparation.
- Pilot scale manufacturing.
- Liquids requiring prefiltration, such as serum-containing media.
- Sterile filtration of buffers.
- Point-of-use filtration for laboratory water.
- Reduce mycoplasma with the 0.1 µm pore size.
Materials of ConstructionFilter Media: Supor membrane (hydrophilic polyethersulfone)
Housing, Vent Plug, and Filter Support: Polypropylene
Sealing Method: Thermal bonding
Filling Bell: Polycarbonate
Pore Size
0.1/0.1, 0.2/0.2, 0.8/0.2 and 0.8/0.45 µm
Effective Filtration AreaAcroPak 500 capsules: 500 cm
2AcroPak 1000 capsules: 1000 cm
2
AcroPak 1500 capsules: 1500 cm
2
DimensionsDiameter: 6.9 cm (2.7 in.)
Overall Length (without Filling Bell):
500 series: 14.5 cm (5.7 in.)
1000 series: 19.3 cm (7.6 in.)
1500 series: 22.9 cm (9.0 in.)
Inlet/Outlet ConnectionsAcroPak 500 & 1000 series:
6.4 - 12.7 mm (1/4 - 1/2 in.) stepped hose barb with filling bell on outlet
AcroPak 1500 series:
12.7 mm (1/2 in.) straight hose barb, no filling bell on outlet
Typical Hold-up Volume(with 10 psi air purge)
500 series: 30 mL
1000 series: 45 mL
1500 series: N/A
Maximum Operating Temperature60 °C (140 °F) at 2.1 bar (210 kPa, 30 psi)
Maximum Operating PressureContinuous: 4.1 bar (410 kPa, 60 psi) at ambient temperature
Recommended Integrity Test
Minimum Bubble Point — Water0.2 µm: 3.5 bar (350 kPa, 51 psi)
0.45 µm: 1.7 bar (170 kPa, 24 psi)
60% IPA/40% H2O (v:v)
0.1 µm: 2.4 bar (240 kPa, 35 psi)
Typical Water Flow RateL/min at 0.07 bar (7 kPa, 1 psi)
|
| |
500 series |
1000 series |
1500 series |
|
|
|
|
| 0.1/0.1 µm |
0.2 (0.2) |
0.4 (0.3) |
|
|
|
|
|
| 0.2/0.2 µm |
0.6 (0.4) |
1.1 (0.8) |
1.6 (1.1) |
|
|
|
|
| 0.8/0.2 µm |
1.1 (0.8) |
1.6 (1.1) |
2.2 (1.5) |
|
|
|
|
| 0.8/0.45 µm |
1.3 (0.9) |
2.5 (1.7) |
|
|
Bacterial Retention
0.1/0.1 µm capsules: Lot samples retain a minimum of 107 cfu/cm2 of A. laidlawii challenge per modified ASTM F838-83
0.2 µm capsules: Lot samples retain a minimum of 107 cfu/cm2 of B. diminuta per modified ASTM F838-83
Endotoxin Level
< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test
Biological Safety
Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>
Sterilization
Sterilized by gamma irradiation; if desired, autoclave once only prior to use at 121 - 123 °C (250 - 253 °F) for a maximum of 20 minutes.